Anhydrous Ammonia Tank Testing
Craig's Restoration & Repair offers a
unique and expert view in tank inspections because of our "R" stamp
welding background. After repairing several legible
data plate anhydrous ammonia vessels we feel we have a better understanding of the
construction and problem areas of a nurse tank. We
also take extra measures in providing accurate and thorough tests, such
as:
- Providing a two man crew ensuring that nothing is overlooked.
- Using certified testing gauges to keep from over-pressurizing the vessel.
- Removing painted area to accurately interpret thickness of vessel.
- Regular servicing and recalibration of our testing equipment.
We take pride in our testing because we know what's at Stake
- YOU!
Test Provided
Craigs Restoration & Repair provides
DOT certified Anhydrous Ammonia Nurse Tank Testing in Compliance with DOT
SP13554. Our test consists of three
phases. Each phase must pass in order for the tank
to pass. If a tank passes it will be tested again in
five years in order to continue use. If it fails it
may not be used as a pressure retaining
vessel. Phases include:
Visual
The visual phase consists of visually
checking for dents, gouges, cracks, pits and defects.
Thickness
Test completed using ultrasonic testing
equipment.
Hydro Test
Tanks are required to be filled with
water and hydro tested at 375 psi. for a minimum of 10 minutes this
ensures the integrity of the vessel for use with hazardous materials.